7-18
7.2.16 Heating Unit Sensor Fault
Heating Unit Sensor
Fault
Disconnect the EZJ94 board
CN7 connector and reconnect it.
Replace the heating unit.
Replace the EZJ94 board.
Resume the
operation.
Does the fault recur?
Does the fault recur?
Yes
No
・
Clear the fault.
・
From the maintenance screen,
place the heating unit in the
operating mode.
・
Restart the IJ printer.
Yes
No
Replace the EZJ93 board.
Does the fault recur?
Yes
No
- On detecting this fault, the IJ printer automatically sets the “Ink temperature
correction” to (disable).
“System environment setup Ink temperature correction (enable)
Æ
(disable)
After getting rid of the fault, reset the Ink temperature correction to (enable).
“System environment setup Ink temperature correction (disable)
Æ
(enable)
- In the condition of the “Ink temperature correction (disable),” the “Ink temperature
correction confirmation” message appears each time the power is turned on.
(See “1.2.7 Heating of Ink” in the Instruction manual”.)
Caution
!
・
Clear the fault.
・
From the maintenance screen,
place the heating unit in the
operating mode.
・
Restart the IJ printer.
Summary of Contents for PXR
Page 1: ...Service Manual HITACHI Printer Model PXR Revision December 2008 Version C ...
Page 80: ...3 17 3 17 Circuit diagram of EZJ95 ...
Page 215: ...8 2 8 1 2 Circulation system diagram PXR P ...
Page 216: ...8 2 Air system diagram PXR P 8 3 ...
Page 217: ...8 4 8 3 Electrical Connection Diagram 8 3 1 Electrical Connection Diagram PXR D ...
Page 218: ...8 5 8 3 2 Electrical Connection Diagram PXR H ...
Page 219: ...8 3 3 Electrical connection diagram PXR P 8 6 ...