49
Input/Output/Measurement Specifications
4.2
Input/Output/Measurement
Specifications
Standard Specifications
Measurement function
Abbreviation
Measurement function
Voc
Open-circuit voltage
measurement
BPD TEST
Bypass diode
measurement
SELF CHECK
Self-check
Function configuration
SELF CHECK/OFF/Voc/BPD TEST
Input terminal
P(+)
terminal: Connected to positive terminal of
PV string
N(−)
terminal: Connected to negative terminal of
PV string
Maximum input voltage 1000 V DC
Maximum rated voltage
to earth
600 V DC (No measurement category)
(1) Voc mode
Measurement item
Open-circuit voltage
Displayed item
Open-circuit voltage
(Reference value and comparison value when
comparison display is enabled)
Measurement range
0 V to 1000 V DC (Displayed up to 1200 V DC)
Response time
Within 1 sec.