4.
Set the detection target, sensitivity, and the target validity.
•
Sensitivity
: The percentage of the body part of an acceptable target that crosses the pre-defined
region. Sensitivity = 100 - S1/ST × 100. S1 stands for the target body part that crosses the pre-
defined region. ST stands for the complete target body. The higher the sensitivity value, the more
easily the alarm can be triggered.
•
Detection Target
: Human and vehicle are available. If the detection target is not selected, all the
detected targets will be reported, including humans and vehicles.
•
Target Validity
: If you set a higher validity, the required target features should be more obvious, and
the alarm accuracy would be higher. A target with less obvious features would be missed.
Figure 5, Set Rule
5.
Optional
:
You can set the parameters of multiple areas by repeating the above steps.
6.
For arming schedule settings, refer to
Set Arming Schedule. For linkage method settings, refer to
Linkage Method Settings.
7.
Click
Save
.
Set Region Exiting Detection