GigE Line Scan Camera
·
User Manual
32
Figure 7-18
Set Burst Frame Count
When Acquisition Burst Frame Count is 1, it is in single frame trigger mode. When Acquisition
Burst Frame Count is larger than 1, it is in multi-frame trigger mode. If Acquisition Burst Frame
Count is n and when inputting 1 trigger signal, the camera stops acquiring images after exposing n
times and outputs n frame images. The sequence diagram of burst frame count is shown below.
Figure 7-19
Sequence Diagram
The sequence diagram above uses rising edge as trigger activation, and the camera’s height
parameter is 4.
7.6.2 Trigger Activation
The specific trigger activation parameters may differ by camera models.
The camera supports trigger acquisition in the rising edge, falling edge, any edge, level high or level
low of the external signal. The principle and parameter of trigger activation are shown below.
Table 7-6
Trigger Activation Principle and Parameter
Trigger Activation Parameter
Parameter Value Principle
Rising Edge
Acquisition Control >
Trigger Activation
Rising Edge
The camera receives signal and
triggers when the level signal sent
by the external device is in the
rising edge.