GigE Line Scan Camera
·
User Manual
21
Trigger Source
Parameter
Parameter
Value
Principle
Shaft encoder
control
Acquisition Control >
Trigger Source
Encoder
Module Out
This trigger source uses shaft encoder module
to receive signal A and signal B with phase
difference. After internal computing of the
module, the outputted signal can be used as
camera’s trigger signal.
Frequency
converter
control
Acquisition Control >
Trigger Source
Frequency
Converter
This trigger source allows different frequency
between trigger camera signal and required
input signal.
Action
command
trigger
Acquisition Control >
Trigger Source
Action 1
The action command sends trigger signal to
the camera to acquire images. You can select
this trigger source only when the frame trigger
mode is set.
Free trigger
Acquisition Control >
Trigger Source
Anyway
Use trigger sources mentioned above to send
trigger signal to the camera to acquire images.
The trigger source may differ by camera models.
These trigger sources are valid only the frame trigger mode, line trigger mode or line + frame
trigger mode is enabled.
In line + frame trigger mode, if the trigger source selected and trigger parameters configured
for the frame trigger and the line trigger are the same, and then the first signal of the trigger
source is used as the frame trigger signal to let the camera acquire images. The subsequent
signals used as the line trigger signal to acquire images until the completion of one frame
image.
7.5.1 Set Software Trigger
The camera supports software trigger. When the software trigger is selected, the client software
sends commands via Gigabit Ethernet to camera to acquire and transmit images.
Steps:
1.
Click Acquisition Control > Trigger Selector.
2.
Select Frame Burst Start as Trigger Selector, and On as Trigger Mode.
Summary of Contents for MV-CL021-40GM
Page 1: ...GigE Line Scan Camera User Manual ...
Page 126: ...UD24388B ...