GigE Line Scan Camera
·
User Manual
25
Figure 7-9
Process Logic of 1 Tick
Figure 7-10
Process Logic of 2 Ticks
Figure 7-11
Process Logic of 4 Ticks
For other camera models, Encoder Trigger Frequency outputs 4 signals by default.
4.
Set Encoder Counter Mode.
Ignore Direction means that both forward and backward direction will count.
Follow Direction means that the forward direction is valid, and Encode Counter will
increase.
Backward Direction means that the backward direction is valid, and Encode Counter will
increase.
Summary of Contents for MV-CL021-40GM
Page 1: ...GigE Line Scan Camera User Manual ...
Page 126: ...UD24388B ...