RS-644 Standard Output
The camera adopting RS-422 standard output signal cannot directly connect to RS-644 standard.
When connecting RS-644 standard output, it is required to add a resistance network in camera’s
output location. In order to make sure the normal operation of output circuit, it is required to
connect camera’s ground signal with external ground signal.
9.2.3 Bi-Direction I/O Circuit
The bi-directional I/O can be used as the input signal and output signal, and its internal circuit is
shown below.
Figure 9-3
Bi-Directional I/O Circuit
Set Line 2 as Input
Logic 0 input level: 0 VDC to 0.5 VDC (GPIO2 pin).
Logic 1 input level: 1.5 VDC to 30 VDC (GPIO2 pin).
With the condition of 100 Ω and 5 VDC, the logic level and electrical feature of configuring GPIO2
as input are shown below.
Logic 1
Input Level
Logic 0
Input Level
Internal Logic
TDR
TDF
Figure 9-4
Input Logic Level