Chapter 8 I/O Output
8.1 Select Output Signal
The selectable output signal line may differ by camera models.
The camera has multiple differential output lines or bi-directional configurable lines. The method
of setting bi-directional configurable line as output line as follows:
Steps:
1.
Click Digital IO Control, and select specific line as Line Selector.
2.
Set Strobe as Line Mode.
3.
(Optional) Set Line Format according to actual demands. Differential stands for the differential
signal.
Figure 8-1
Select Output Signal
The line format function may differ by camera models.
If a bi-directional configurable line signal is selected as Line Selector and Line Mode is Input
currently, but you cannot set Strobe as Line Mode. The reason is that the bi-directional
configurable line signal is selected as trigger source in one of line trigger/frame trigger/shaft
encoder control/ frequency converter control settings. You should set other line signals as
trigger source in line trigger/frame trigger/shaft encoder control/ frequency converter control
settings all.
8.2 Set Output Signal
The output signal of the camera is switch signal, which is used to control external devices such as
alarm light, light source and PLC. There are two ways to achieve output signal, including line
inverter and strobe signal.