GigE Line Scan Camera
·
User Manual
33
Trigger Activation Parameter
Parameter Value Principle
Falling Edge
Acquisition Control >
Trigger Activation
Falling Edge
The camera receives signal and
triggers when the level signal sent
by the external device is in the
falling edge.
Any Edge
Acquisition Control >
Trigger Activation
Any Edge
The camera receives signal and
triggers when the level signal sent
by the external device is in the
rising edge or falling edge.
Level High
Acquisition Control >
Trigger Activation
Level High
The camera receives signal and
triggers when the level signal sent
by the external device is in the
level high.
Level Low
Acquisition Control >
Trigger Activation
Level Low
The camera receives signal and
triggers when the level signal sent
by the external device is in the
level low.
The setting method for trigger activation is different in frame trigger and line trigger.
Set Trigger Activation in Frame Trigger
Go to Acquisition Control, and set Trigger Activation according to actual demands.
Figure 7-20
Edge Trigger in Frame Trigger
When rising edge or falling edge is selected as Trigger Activation, you can set Trigger Delay.
When level high or level low is selected as Trigger Activation, you can set Trigger Partial Close.
True means that images after complement is outputted after the level trigger ends, and false
means that images output according to the settings of the frame timeout after the level trigger
ends.