GigE Line Scan Camera
·
User Manual
71
Figure 10-32
Set sRGB Mode
10.15 Set AOI
The AOI function may differ by camera models.
The camera supports AOI function that can adjust the brightness and white balance of the entire
image based on the area you selected.
Steps:
1.
Click Analog Control > Auto Function AOI Selector, and select AOI 1 or AOI 2 as Auto Function
AOI Selector.
AOI1 1 is used to adjust the image brightness, and AOI 2 is used to adjust the white balance for
color cameras.
2.
Enter Auto Function AOI Width, Auto Function AOI Height, Auto Function AOI Offset X, and Auto
Function AOI Offset Y according to actual demands.
3.
Enable Auto Function AOI Usage Intensity if AOI 1 is selected as Auto Function AOI Selector. Or
enable Auto Function AOI Usage White Balance if AOI 2 is selected as Auto Function AOI
Selector.
Figure 10-33
Set AOI