Resulting Trigger Line Rate: It refers to the external trigger frequency cameras received after
the external trigger raw line rate is calculated via frequency converter control. It only involves
external trigger signals.
You need to select external trigger sources as Input Source to display specific values in Trigger Line
Rate and Resulting Trigger Line Rate. If N/A is selected as Input Source, these two parameter
values will be 0.
Figure 7-15
View Trigger Line Rate
Make sure that line trigger is enabled and input source value of frequency converter control and
trigger source value of acquisition control is the same before viewing trigger line rate.
7.5.6 Set Action Command Trigger
The action command function may differ by camera models.
The action command allows you to execute actions on multiple cameras at roughly the same time
by using a single broadcast protocol message.
The action command function is available only with client software version of V3.1.0 and
higher.
If you want to send action commands that are executed in multiple cameras at exactly the
same time, it is recommended to enable Gev IEEE 1588 first by clicking Transport Layer
Control > Gev IEEE 1588.