GigE Line Scan Camera
·
User Manual
30
7.
(Optional) Enable Periodically Send to enable the client to send commands periodically, and
enter Sending Interval according to actual demands.
The default value of sending interval is 1000 ms, and its range is from 1 ms to 3600000 ms.
8.
(Optional) Enable Request Acknowledgement to display the acknowledgement messages.
Up to 50 messages can be displayed. Once the message quantity exceeds 50, the earliest message
will be automatically deleted.
9.
Click Start Sending.
7.5.7 Set Free Trigger
If the camera enables the frame trigger or line trigger, you can select Anyway as trigger source to
enable the free trigger. At this time, the camera can receive signals of all trigger sources.
Steps:
1.
Click Acquisition Control > Trigger Selector.
2.
Select Frame Burst Start or Line Start as Trigger Selector, and On as Trigger Mode.
3.
Select Anyway as Trigger Source.
Figure 7-17
Set Free Trigger
7.6 Trigger Related Parameters
The configurable trigger related parameters may differ by camera models.
If the camera enables the frame trigger or line trigger, you can set trigger related parameters,
including acquisition burst frame count, trigger activation, trigger delay, trigger cache, and trigger
debouncer. Different trigger modes can set various trigger parameters, and their relation is shown
below.