CoaXPress Area Scan Camera
·
User Manual
74
Parameter
Read/Write
Description
Board Device Type
Read only
It is the device type.
TEC Enable
Read and write Enable it to enable TEC function.
TEC Temperature
Read and write
It sets the max. temperature of sensor.
If actual sensor’s temperature is lower than this
parameter, and TEC function is not enabled.
If actual sensor’s temperature is higher than this
parameter and TEC enable is enabled, and then TEC
function is enabled.
Device Temperature
Selector
Read and write
It selects device temperature, including sensor and
mainboard.
Device Temperature
Read only
It displays the real-time temperature of the device’s
motherboard you selected in Device Temperature
Selector.
Sensor Board
Temperature
Read only
It displays the real-time temperature of the device’s
sensor you selected in Device Temperature Selector.
Fan Control Mode
Read and write
It sets the fan mode.
In auto mode, it includes three-level fan speed: 70,
85 and 100. According to the difference between the
configured sensor temperature (TEC Temperature
parameter) and the actual temperature, adjustment
is made every 30 seconds. If actual temperature -
configured temperature > 2 degrees, fan speed will
increase. Otherwise, fan speed will decrease.
In manual mode, the fan speed is decided by value
set in Fan Speed.
Fan Speed
Read and write It sets the fan speed, and its range is from 40 to 100.
Device Command
Timeout
Read only
It counts the timeout of command.
Device Reset
Write only
Click Execute to reset the device.
Summary of Contents for CoaXPress
Page 1: ...CoaXPress Area Scan Camera User Manual ...
Page 10: ...CoaXPress Area Scan Camera User Manual x Appendix A Camera Parameter Index 85 ...
Page 41: ...CoaXPress Area Scan Camera User Manual 31 Figure 8 18 Set Trigger Debouncer ...
Page 82: ...CoaXPress Area Scan Camera User Manual 72 Figure 11 39 Other Corrections ...
Page 102: ...UD26060B ...