CoaXPress Area Scan Camera
·
User Manual
41
The breakdown voltage is 30 VDC, and keep voltage stable.
To prevent damage to GPIO pin, please connect GND first and then input voltage in Line 2 pin.
Line 2 Configured as Output
The maximum current is 25 mA and the output impedance is 40 Ω.
The relation among external voltage, resistance and the output level low is shown below.
Table 10-5
Parameter of Output Logic Level Low
External Voltage External Resistance VL (GPIO2)
3.3 V
1 KΩ
160 mV
5 V
1 KΩ
220 mV
12 V
1 KΩ
460 mV
24 V
1 KΩ
860 mV
30 V
1 KΩ
970 mV
When the voltage of external resistance (1 KΩ) is pulled up to 5 VDC, the logic level and electrical
feature of configuring Line 2 as output are shown below.
Logic 1
Output Level
Logic 0
Output Level
Internal
Logic
TDR
TDF
TF
TR
Figure 10-7
Output Logic Level