CoaXPress Area Scan Camera
·
User Manual
69
Figure 11-35
Correcting Image via Setting Parameters
The LSC correction can be done only when the camera is in full resolution. If you are only
interested in certain details in the image, you can use the ROI function.
11.23.2 LSC Sequencer
Without stopping camera’s image streams, LSC sequencer function can periodically take pictures of
collected images via setting multiple groups of brightness parameter tables according to the
default sequencer parameter group or manually setting sequencer parameter group. Therefore,
the camera can process images of inconsistent uniformity due to different light sources.
The LSC sequencer function may differ by camera models.
Steps:
1.
Click Shading Correction, select LSC Correction as Shading Selector.
2.
Select tables from LSC Table Selector ranging from Table 0 to Table 7 according to actual
demands.
When using eight LSC tables, the default sequencer order is from Table 0 to Table 7 in turn.
Summary of Contents for CoaXPress
Page 1: ...CoaXPress Area Scan Camera User Manual ...
Page 10: ...CoaXPress Area Scan Camera User Manual x Appendix A Camera Parameter Index 85 ...
Page 41: ...CoaXPress Area Scan Camera User Manual 31 Figure 8 18 Set Trigger Debouncer ...
Page 82: ...CoaXPress Area Scan Camera User Manual 72 Figure 11 39 Other Corrections ...
Page 102: ...UD26060B ...