Figure 8-8
Set Counter Trigger
When using counter trigger, you need to set relevant parameters of Counter And Timer Control.
Table 8-2
Description of Counter and Timer Control
Parameter
Read/Write
Description
Counter Selector
Read and write
It selects counter source. Counter 0 is available only
at present.
Counter Event Source
Read and write
It selects the signal source of counter trigger. Line 0,
Line 2 or Link Trigger 0 is available. This parameter
is disabled by default.
Counter Reset Source
Read and write
It selects the signal source of resetting counter.
Software is available only. This parameter is
disabled by default.
Counter Reset
Write is available under
certain condition
It resets counter and it can be executed when
selecting Software as Counter Reset Source.
Counter Value
Read and write
It is the counter value with the range of 1 to 1023.
Counter Current Value Read only
It displays the number of executed external trigger.
Summary of Contents for CoaXPress