CoaXPress Area Scan Camera
·
User Manual
44
NPN Device
If the VCC of NPN device is 24 VDC, and it is recommended to use 4.7 KΩ pull-up resistor.
If the VCC of NPN device is 12 VDC, and it is recommended to use 1 KΩ pull-up resistor.
Camera Power
Opto-isolated
Output
Camera Power
Ground
PWR
VCC
NPN Power
Signal Line
NPN Power
Ground
NPN Device
Opto-isolated
Signal Ground
GND of PWR
GND of VCC
●
●
●
Figure 10-12
Line 1 Connecting to NPN Device
10.2.3 Line 2 Wiring
As bi-direction I/O Circuit, Line 2 can be used as both input signal and output signal.
Line2 Configured as Input
When the camera uses Line 2 as hardware trigger source, wirings are different with different
external devices of input signal.
PNP Device
It is recommended to use 330 Ω pull-down resistor.
Camera Power
Bi-direction I/O
Camera Power
Ground
PWR
VCC
PNP Power
Signal Line
PNP Device
GND of PWR and VCC
PNP Power
Ground
●
●
●
Figure 10-13
Line 2 Connecting to PNP Device as Input
NPN Device
If the VCC of NPN device is 24 VDC, and it is recommended to use 4.7 KΩ pull-up resistor.
If the VCC of NPN device is 12 VDC, and it is recommended to use 1 KΩ pull-up resistor.