CoaXPress Area Scan Camera
·
User Manual
27
Sources
Parameters
Software
Trigger
Hardware
Trigger
Counter
Trigger
Link Trigger
Free Trigger
Trigger Activation
×
√
√
√
√
Trigger Debouncer
×
√
×
×
×
8.5.1 Set Burst Frame Count
Under external trigger mode, you can set burst frame count. Click Acquisition Control >
Acquisition Burst Frame Count, enter Acquisition Burst Frame Count, and its range is from 1 to
1023.
Figure 8-12
Set Burst Frame Count
When Acquisition Burst Frame Count is 1, it is in single frame trigger mode. When Acquisition
Burst Frame Count is larger than 1, it is in multi-frame trigger mode.
If Acquisition Burst Frame Count is n and when inputting 1 trigger signal, the camera stops
acquiring images after exposing n times and outputs n frame images. The sequence diagram of
burst frame count is shown below.
Trigger
Sensor
exposure
Burst Count = 4
Figure 8-13
Sequence Diagram of Burst Frame Count
Here we take the rising edge as the trigger signal.
Summary of Contents for CoaXPress
Page 1: ...CoaXPress Area Scan Camera User Manual ...
Page 10: ...CoaXPress Area Scan Camera User Manual x Appendix A Camera Parameter Index 85 ...
Page 41: ...CoaXPress Area Scan Camera User Manual 31 Figure 8 18 Set Trigger Debouncer ...
Page 82: ...CoaXPress Area Scan Camera User Manual 72 Figure 11 39 Other Corrections ...
Page 102: ...UD26060B ...