143
4/2018
113175421
XR14S/16S/18S/21S/26S/30S
Hooklift Multilift XR S
Service Manual
>>>
FAULTS
01.01
MEDIUM
EEPROM
FAILURE
ERROR DETECTED
ON NON VOLATILE
MEMORY
ERROR DISPLAYED ON DISPLAY, CAN MODULE
SWITCHED TO PRE-OPERATIONAL STATE AND
SYSTEM WILL SELF RESET AUTOMATICALLY.
WAIT, UNTIL THE SYSTEM HAS STARTED.
01.02
SEVERE
FLASH
MEMORY
FAILURE
INCORRECT
CHECKSUM ON
FLASH MEMORY
ERROR DISPLAYED ON DISPLAY, SYSTEM
SWITCHED TO ERROR STATE.
SYSTEM MUST
BE POWER CYCLED.
01.03
MEDIUM
STACK
MEMORY
FAILURE
INCORRECT
SIZES IN CAN
OPEN PROTOCOL,
INCORRECT
DATAFLOW, OR
STACK OVERFLOW
ERROR DISPLAYED ON DISPLAY, CAN MODULE
SWITCHED TO PRE-OPERATIONAL STATE AND
SYSTEM WILL SELF RESET AUTOMATICALLY.
WAIT, UNTIL THE SYSTEM HAS STARTED.
01.04
MEDIUM
RAM
MEMORY
FAILURE
INCORRECT RAM
AND/OR HARDWARE
IDENTIFICATION
ERROR DISPLAYED ON DISPLAY, CAN MODULE
SWITCHED TO PRE-OPERATIONAL STATE AND
SYSTEM WILL SELF RESET AUTOMATICALLY.
WAIT, UNTIL THE SYSTEM HAS STARTED.
ERROR
CODE
1.2
(CATEGORY)
DESCRIPTION CAUSE
ACTION
Error codes, control unit
POSSIBLE ERRORS INSIDE CONTROL UNIT
WHEN INTERNAL OR COMMUNICATION ERRORS OCCUR ON CONTROL UNIT FOLLOWING DIFFERENT ERROR
CODES ARE DISPLAYED ON THE 7SEGMENT DISPLAYS. THEY ARE DISPLAYED ACCORDING TO THIS SCENARIO:
ERR 1ST -> ERR 2ND
.
ERROR CATEGORIES
1.2
LOW
INFORMATION SHOWN ON DISPLAY AND CORRESPONDING FUNCTION STOPPED.
1.2
MEDIUM INFORMATION SHOWN ON DISPLAY, AND THEN IS SYSTEM RE-STARTED AUTOMATICALLY
TO REINITIATE SYSTEM CORRECTLY.
1.2
SEVERE INFORMATION SHOWN ON DISPLAY, CAN-BUS DE-ACTIVATED AND SYSTEM LOCKED.
NEEDS POWERCYCLE TO RESTART.
Summary of Contents for Hooklift Multilift XR S Series