7-21. PRESSURE
TRANSDUCER
This component controls the AIF filter pump by sensing the
pressure in the expansion chamber.
Voltage range is 0.5 to 4.5 VDC, corresponding to a pressure
range of 0 to 30 PSIG
A messured pressure below -1.5 PSI or above 32 PSI may
indicate a failed transducer, it has become disconnected, or a
clogged expansion chamber.
To view the the pressure, press
and at the same time
and “*HP* *INFO*” shows in the display, followed by “1. E-
LOG”. Press until “14. AIF” shows in the display. Press
until “PRESSURE SENSOR” shows in the left display.
Press
X
button to show pressure in PSI.
An over-pressure issue can also indicate a return valve failing
to open, instead of a faulty transducer or a clogged chamber.
In case of a clogged expansion chamber, remove the clean-
out plugs at each end of the chamber to clean the obstructions
inside the chamber. Photo at left.
Extra long fill times or oil bubbling at end of an AIF cycle may
be signs of a clogged expansion chamber or faulty transducer.
Replacement:
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove the left side panel.
2. Pull-out on the clip, while pushing up on the wire harness
connector, at the top of the tranducer, to remove wires.
3. Using a 1-1/16” wrench, remove the tranducer from the
expansion chamber.
4. Using pipe thread sealant, install new tranducer in reverse
order and restore power to the unit.
Clean-out Plugs
Expansion Chamber
Sept. 2009
Summary of Contents for LOV LVG-102
Page 2: ...Model LVG 102 103 104 2...
Page 21: ...Model LVG 102 103 104 3 6...
Page 71: ...Model LVG 102 103 104 8 7 1 2 1 3 4 6 5 7 8 9 10 11 12 5 13 14 15 14 17 16 4 Feb 2011...
Page 89: ...Model LVG 102 103 104 A 2 May 2016...
Page 90: ...Model LVG 102 103 104 A 3 May 2016...
Page 91: ...Model LVG 102 103 104 A 4 May 2016...
Page 92: ...Model LVG 102 103 104 A 5 May 2016...
Page 93: ...Model LVG 102 103 104 A 6 May 2016...
Page 94: ...Model LVG 102 103 104 A 7 May 2016...
Page 95: ...Model LVG 102 103 104 A 8 May 2016...
Page 96: ...Model LVG 102 103 104 A 9 May 2016...