7-9. FILTER PUMP & MOTOR
The 2 most common causes for a fryer not to pump oil are that
the pump is clogged, or the thermal overload switch has been
tripped on the motor. The pump and motor is located on the
rear of the fryer.
To reset the thermal overload switch:
1. Remove the right side panel and locate pump and motor in
the rear of the fryer. If the motor is hot, allow it to cool for
about 5 minutes.
2. Since it takes some effort to reset the switch, use a tool,
such as a Phillip’s-head screwdriver, to press against the
reset button until a “click” is heard.
To remove debris from pump:
1. Loosen four Allen head screws on the end of pump and
remove cover. (Removing the bottom rear panel may help
in accessing the set screws.)
2. The inside is now exposed leaving a rotor and five teflon
rollers. Clean the rotor and rollers.
3. To reassemble, place rotor on drive shaft, and place roller
into rotor.
A small amount of grease might be needed to hold the
bottom roller into place until cover plate is put on. Make
sure O-ring is in proper position on plate.
Indicators, on the side of the two halves of the pump,
must align together.
Aug. 2008
Summary of Contents for LOV LVG-102
Page 2: ...Model LVG 102 103 104 2...
Page 21: ...Model LVG 102 103 104 3 6...
Page 71: ...Model LVG 102 103 104 8 7 1 2 1 3 4 6 5 7 8 9 10 11 12 5 13 14 15 14 17 16 4 Feb 2011...
Page 89: ...Model LVG 102 103 104 A 2 May 2016...
Page 90: ...Model LVG 102 103 104 A 3 May 2016...
Page 91: ...Model LVG 102 103 104 A 4 May 2016...
Page 92: ...Model LVG 102 103 104 A 5 May 2016...
Page 93: ...Model LVG 102 103 104 A 6 May 2016...
Page 94: ...Model LVG 102 103 104 A 7 May 2016...
Page 95: ...Model LVG 102 103 104 A 8 May 2016...
Page 96: ...Model LVG 102 103 104 A 9 May 2016...