Model LVG-102, 103, 104
7-17
This component is located behind the left control panel and
regulates voltage to the filter motor.
Replacement:
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove left side panel.
2. Label and remove wires from relay.
3. Using a 5/16” wrench, remove nuts securing the relay and
remove relay from fryer.
4. Install new relay in reverse order.
The gas control valve assembly controls flow of gas to the
pilot and the main burner. Valve has two 24 volt coils, which
are regulated by terminals PV and MV on the valve. For gas
flow to the pilot, 24 VAC must be present between the PV and
COM terminals.For gas flow to the main burner, 24 VAC must
be present between the MV and COM terminals.
TO AVOID INJURY, PROPERTY DAMAGE, OR
EXPLOSION, BEFORE REPLACING STARTING THIS
PROCEDURE, DO THE FOLLOWING:
• MOVE THE POWER/PUMP SWITCH TO THE
“OFF” POSITION.
• DISCONNECT THE MAIN CIRCUIT BREAKER
AT THE WALL, OR UNPLUG THE POWER CORD.
• TURN OFF THE MAIN GAS SUPPLY TO THE
FRYER AND DISCONNECT AND CAP THE SUPPLY
LINE TO FRYER.
7-13. FILTER MOTOR RELAY
7-14. GAS CONTROL VALVES
Aug. 2008
Summary of Contents for LOV LVG-102
Page 2: ...Model LVG 102 103 104 2...
Page 21: ...Model LVG 102 103 104 3 6...
Page 71: ...Model LVG 102 103 104 8 7 1 2 1 3 4 6 5 7 8 9 10 11 12 5 13 14 15 14 17 16 4 Feb 2011...
Page 89: ...Model LVG 102 103 104 A 2 May 2016...
Page 90: ...Model LVG 102 103 104 A 3 May 2016...
Page 91: ...Model LVG 102 103 104 A 4 May 2016...
Page 92: ...Model LVG 102 103 104 A 5 May 2016...
Page 93: ...Model LVG 102 103 104 A 6 May 2016...
Page 94: ...Model LVG 102 103 104 A 7 May 2016...
Page 95: ...Model LVG 102 103 104 A 8 May 2016...
Page 96: ...Model LVG 102 103 104 A 9 May 2016...