Model LVG-102, 103, 104
7-9
8. Connect new temperature probe to connector and fasten
connector onto control panel.
9. Replace control panel and reconnect power to vat.
10. Fill vat by pressing and holding a button until
*FILTER* *MENU* shows in the display. Then once
“1.AUTO FILTER” shows in the display, press 4
times until “5.FILL POT FROM DRN PAN” shows in
display. Press
√
button; “FILL POT FROM DRN PAN”
“YES NO” displays. Press
√
button again, display shows
“FILLING” “STOP?”and oil fills vat. Press
√
button again,
display shows “FILL POT FROM DRN PAN” “YES NO”.
When vat is full, press
X
twice to return to normal
operation.
Each vat has a solenoid plumbed-into the oil return lines. They
are normally closed, but open when power is supplied, such as,
the controls are filling the vats.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove both top and bottom rear panels, or a side panel,
depending upon the location of the solenoid.
Checkout:
2. Follow the wires from solenoid and through conduit and
then cut wires. Strip wires back and take an ohm reading:
120 Volts - 60Hertz
50 Ohms
220-240 Volts -50/60 Hertz
230 Ohms
7-6. TEMPERATURE PROBE
REPLACEMENT
(Continued)
7-7. SOLENOID VALVES
Feb. 2011
Summary of Contents for LOV LVG-102
Page 2: ...Model LVG 102 103 104 2...
Page 21: ...Model LVG 102 103 104 3 6...
Page 71: ...Model LVG 102 103 104 8 7 1 2 1 3 4 6 5 7 8 9 10 11 12 5 13 14 15 14 17 16 4 Feb 2011...
Page 89: ...Model LVG 102 103 104 A 2 May 2016...
Page 90: ...Model LVG 102 103 104 A 3 May 2016...
Page 91: ...Model LVG 102 103 104 A 4 May 2016...
Page 92: ...Model LVG 102 103 104 A 5 May 2016...
Page 93: ...Model LVG 102 103 104 A 6 May 2016...
Page 94: ...Model LVG 102 103 104 A 7 May 2016...
Page 95: ...Model LVG 102 103 104 A 8 May 2016...
Page 96: ...Model LVG 102 103 104 A 9 May 2016...