Model LVG-102, 103, 104
7-14
This pump keeps the vats filled and is used in the Automatic
Intermittent Filter process.
Replacement:
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove the right side panel.
2. Using 1” wrench, loosen both fitting on each side of pump.
3. Using a Phillip’s-head screwdriver, remove the 4 screws
securing the bottom of pump.
4. Disconnect the wires in the rear of the pump and pull
assembly from fryer.
5. Pull fittings from faulty pump and attach fittings to the new
pump, in the same orientation.
6. Install new pump assembly in fryer, in reverse order and
then reconnect power to fryer.
This electronic board controls the Automatic Intermittent
Filtering process.
Replacement:
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove the left side panel.
2. Using a 3/8” socket or nut driver, remove nuts securing the
cover and remove cover.
3. Pull connectors from PC board.
4. Using a 5/16” socket, remove 6 nuts securing the board
and remove it from the fryer.
5. Install in reverse order. The control connectors are colored-
coded; Left-Red; Middle-White; Right-Blue.
7-10. AIF PUMP
7-11. AIF PC BOARD
Aug. 2008
Summary of Contents for LOV LVG-102
Page 2: ...Model LVG 102 103 104 2...
Page 21: ...Model LVG 102 103 104 3 6...
Page 71: ...Model LVG 102 103 104 8 7 1 2 1 3 4 6 5 7 8 9 10 11 12 5 13 14 15 14 17 16 4 Feb 2011...
Page 89: ...Model LVG 102 103 104 A 2 May 2016...
Page 90: ...Model LVG 102 103 104 A 3 May 2016...
Page 91: ...Model LVG 102 103 104 A 4 May 2016...
Page 92: ...Model LVG 102 103 104 A 5 May 2016...
Page 93: ...Model LVG 102 103 104 A 6 May 2016...
Page 94: ...Model LVG 102 103 104 A 7 May 2016...
Page 95: ...Model LVG 102 103 104 A 8 May 2016...
Page 96: ...Model LVG 102 103 104 A 9 May 2016...