Service menu - appliance test
29
Service instructions
Touch the "OK" field.
Changes saved.
Canceling the selection Touch the "Back" field.
Relay overview
Relay
Connec-
tor
No.
Description
Instruction
K1
X10
2
Main contactor Q1
Reconnect the line from X10.2 to X12.5 and to as-
sign a reserve relay to it.
K1
X11
1
POS A
Reconnect the line from X11.1 to X12.5 and to as-
sign a reserve relay to it.
K2
X11
2
POS B
Reconnect the line from X11.2 to X12.5 and to as-
sign a reserve relay to it.
K3
X12
2
Magnetic valve manual rinse
Reconnect the line from X12. 2 to X12. 5 and to
assign a reserve relay to it.
K4
X12
3
Magnetic valve for water vapor
elimination K12
Reconnect the line from X12.3 to X12.5 and to as-
sign a reserve relay to it.
K5
X12
4
Siphon pump G24
Reconnect the line from X12.4 to X12.5 and to as-
sign a reserve relay to it.
K6
X12
5
Backup relay K6
Reconnect the line from X12.5 to X12.5 and to as-
sign a reserve relay to it.
K8
X17
1
Solenoid fresh air M8
Reconnect the line from X17.1 to X12.5 and to as-
sign a reserve relay to it.
K17
X12
1
Circulating pump G16
Reconnect the line from X12.1 to X12.5 and to as-
sign a reserve relay to it.
Dismantling and re-
programming
After changing the control board the original state is restored. Thus,
the backup relay is not used unnecessarily.
Establish the original condition of the wiring (from X12. 5 to Xx).
Calling up the "Backup relay" in the Service menu.
Select "OFF" using the roller.
The backup relay is deactivated.
Touch the "OK" field.
Changes saved.
5.23 Status overview direct access
Description
Direct access in the status overview.
Display of all processes and temperature in ongoing operation.
10015160-0ASAE-A