Error messages
46
Service instructions
9.2 Cooking chamber sensor defective (694, 695)
Description Emergency operation is activated automatically and displayed. The
core temperature sensor takes over the function of the cooking
chamber sensor. Cooking program with core temperature sensor is
no longer available.
Location The cooking chamber sensor is in the top right of the cooking
chamber.
Naming on the circuit
diagram
B2
Troubleshooting Dismount unit cover.
Check contacting on control board A1, X25.
Remove existing cooking chamber sensor from the control board
A1, X25 and plug in new cooking chamber sensor.
The fault message disappears. Replace cooking chamber
sensor.
The fault message is still displayed. Replace control board.
Function check The measurement values can be called up in the status overview.
10015160-0ASAE-A