Service menu - appliance test
21
Service instructions
5.9 Emptying the water
Description Water drainage removes water residue from the unit to prevent frost
damage during transport and idle period.
Requirement
Both water connections are connected to compressed air.
The pressure may not exceed 6 bar.
The cooking chamber temperature is < 130°C.
Overview
Starting to drain the water
Touch the "START" field.
Start of the automatic water drainage.
Display of the cooking chamber temperature and remaining
time.
Canceling the water
drainage
Touch the "STOP" field.
5.10 Setting the set-up height
Overview
Setting the set-up height
Set the set-up height by adjusting the rollers.
Touch the "OK" field.
Changes saved.
Canceling the selection
Touch the "Back" field.