Service menu - appliance test
18
Service instructions
5.7.1 Check calibration
Prerequisite Calibrated digital temperature measurement device.
The temperature in the cooking chamber is < 100°C.
Fix internal core temperature sensor and temperature sensor of
external measurement device in the cooking chamber.
Use a grill rack for this.
Point the sensor tips upward in order to prevent measurement
errors.
Checking the calibration
Touch the "START" field.
The cooking chamber is heated up to 100°C.
Display of the current temperature on the touch screen.
Wait until the cooking chamber temperature on the touch screen
indicates 100°C (± 1°C).
Compare displayed cooking chamber temperature with
temperature of external measurement device.
The external measurement device must display a temperature
between 99°C – 99.5°C.
If the value is within the range, end checking.
Touch the "STOP" field.
If the value is outside of the range, calibration must be done.
Continue with calibration
(see „5.7.2 Calibrate cooking chamber
sensor‟, Page 19)
.