61
8 Appendix
8.3 Interface XS10 PLC, Robot
Pin no.:
Function
Addition
1
Output: Device ready for dosing
Optocoupler output
2
Reserved, do not assign!
3
Output: fault
Optocoupler output
4
Reserved, do not assign!
5
Start X input
Optocoupler input
6
Start Y input
Optocoupler input
7
8
Internal ground output
9
Input: Potential
for all outputs
10
Input: Reset fault
Optocoupler input
11
Start Z input
Optocoupler input
12
Output: Refill tank
Optocoupler output
13
Output: Tank empty
Optocoupler output
14
Input: Potential
for all optocoupler inputs
15
Output: in24V supply
The internal power supply on Pin 8 and 15 is intended for reading in external dry contacts. It is
rated for a maximum of 50 mA.
Do NOT connect a power supply or heavier loads to these outputs!
The optocoupler inputs can be connected to +24 V or alternatively to ground.
The corresponding counter potential is connected for all inputs of this interface
together to Pin 14.
The optocoupler outputs can be supplied for the query with internal or
external (5-24 V DC) voltage. They switch through the potential applied
to Pin 9 (max. 50 mA).
Example: Input external voltage, positive rail switched
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
+24VDC,
50 mA
internal Ground
external
+24VDC
Start X
Start Y
Start Z
Reset
Reset Error
RC15 DC Drive
Controller Input
PLC / Robot
Output
Start X
Start Y
Start Z
Ground output
external Ground
Do not connect!
Do not connect!
Do not connect external 24VDC to pin 15!
Common potential inputs
Summary of Contents for 1880232