48
2 Description
2.6 Connections (Rear Side)
21
Power Connection
100 - 240 VAC, 50/60 Hz with glass tube miniature fuse 2A,
semi time-lag, 5 x 20 mm
22
Pneumatic Connection Reservoir
Regulated air pressure supply (0 - 7 bar, 0 – 100 PSI) to the reservoir, for
air hose OD Ø 6 mm , ID Ø 4 mm.
23
Main air connector
4 - 8 bar (58 PSI - 116 PSI) for air hose OD Ø 6 mm, ID Ø 4 mm
24
Connection XS 18,
not in use
25
Connection XS 1 Start
Use to connect foot switch
97201
26
Connection XS 2 Product reservoir
Is used to connect the product reservoir. Only one reservoir can be actuated.
27
Connection XS 10 PLC
Parallel interface for connection of a programmable logic controller.
28
Connector Pump
29
Connection XS 16: Rotor
Is used to connect the rotor.
21
22
23
24
25
26
27
28
29
100-240 VAC, 50
/60 Hz
Fuse: 2A T (time
-lag)
Pump
XS10 PLC
XS2 Reservo
ir
XS1 Start
XS16
XS18
Henkel AG & Co. KGaA
Standort Mün
chen
Gutenbergstr
. 3
D-85748 Garching
Power Consumpti
on: 100 W
Order No. 188
0232
Made in German
y
Place for Serial N
o. Sticker
P out
P in 4-6 bar
+ 0.05
–0.10
Summary of Contents for 1880232