5 Start-up
5.5 Dosing programs [X],[Y],[Z]
To enable fast switching between various types of dispensing settings, up to three dosing
programs can be used. Each dosing program is activated by its own start signal and includes the
settings for the flow rate, dosage quantity or dosing time, the suck back volume and the flow
rate for the suck back.
Options such as the rotor spray, the operating mode or the pump calibration cannot the
switched over by selecting different programs.
For example different dosing programs could be used if two different amounts of product have
to be dispensed onto the same component. The first quantity could be stored in program [X], the
second in program [Y]. Via the corresponding start inputs, the two quantities could be retrieved
as required, avoiding that settings on the control unit have to be changed.
In the External time control mode operating mode up to three different flow rates could be set
up and freely recalled by the higher ranking control.
If different quantities, times, or dosing rates are not required, just the first program [X] is used.
The current dispensing program is displayed
on the main screen of the control unit, where
it can be switched by touching the symbol.
External start signals may also activate and
show different programs.