Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
46
10
Finishing (On-Wall Installation)
A. Facing and Finishing - Studio and Frame
Decorative Fronts
• Facing and/or finishing materials must not interfere
with convection vents, operation of doors, or access
for service. See Figure 10.1 and Figure 10.3.
• Observe all clearances when applying combustible
materials.
• Remove and discard finishing strip before installing
decorative front. See Figure 10.2.
• Use finishing strip to achieve required clearance. See
Figure 10.2 and 10.3.
WARNING! Risk of Fire! DO NOT
apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors.
Figure 10.1 Convection Vent Location
WARNING!
Risk of Overheating and Fire!
Do not allow
convection air vents to be blocked or covered. Non-com-
bustible material must not exceed 4 inches in thickness.
DO NOT BLOCK CONVECTION VENTS
WITH FINISHING MATERIAL
REMOVE CLIPS
FINISHING STRIP
Figure 10.2 Remove Finishing Strip After Installation of Finishing
Material