Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
14
MINIMUM CLEARANCES FROM APPLIANCE OUTER wRAP
MODEL
A
B
C
D*
E**
F***
G
Rough
Opening
(Vent Pipe)
Clearance
to Ceiling
Minimum
Clearance
to Finished
Floor
Clearance
to
Combustible
Flooring
Behind
Appliance
Outer
Wrap
Clear-
ance to
Adjacent
Wall
Front of
Appliance
Measured from
Mesh
Revo-V12
in.
10-1/8
22
4
0
0
12
36
mm
257
559
102
0
0
305
914
Revo-S21
in.
10-1/8
22
4
0
0
12
36
mm
257
559
102
0
0
305
914
Revo-H31
in.
10-1/8
22
4
0
0
12
36
mm
257
559
102
0
0
305
914
D* = Clearance to combustible floor not required due to 4 inch minimum on Dimension C.
E** = The appliance outer wrap can attach directly to combustible material, i.e. sheetrock.
F*** = See Section 10.D and 10.E for combustible and non-combustible mantel legs.
A
(CUT OUT MATERIAL
FOR VENT PIPE)
C
D
F
B
(TO CEILING)
E
APPLIANCE OUTER
WRAP
G
Figure 3.7
E. Clearances (On-Wall and In-Wall)
WARNING! Risk of overheating!
Install appliance a
minimum of 4 inches off of finished floor.
• Convection air flow could be compromised and cause
overheating.
• Decorative fronts will not fit properly.