33
Heat & Glo • REVO-V12, REVO-S21, REVO-H31 Installation Manual • 2273-980 Rev. J • 5/15
Figure 6.9 Install Appliance Outer Wrap
FRAMING
F SHEETROCK
+ APPLIANCE OUTER WRAP
F SHEETROCK
MATERIAL CAN BE
COMBUSTIBLE
I.E. SHEETROCK
F SHEETROCK
+ APPLIANCE OUTER WRAP + HOLE CUT
CUT OUT MATERIAL
FOR VENT
APPLIANCE
OUTER WRAP
APPLIANCE
OUTER WRAP
REMOVE CORRUGATED TEMPLATE PRIOR TO INSTALLING SHEET ROCK
OR PRIOR TO INSTALLING APPLIANCE OUTER WRAP
C. Install Appliance Outer Wrap (On-Wall
Installation)
1. Remove the glass assembly from the firebox by releas
-
ing the two top glass latches and then the two bottom
glass latches. See Figure 12.1.
2. Remove the screws that attach the firebox to the outer
wrap. See Figure 6.8. Separate the firebox from the
outer wrap. Carefully set the firebox aside holding it by
the sides. Do not grab, lift or carry the appliance by the
top heat shield, or component tray. Lay the appliance
on its back to avoid damaging the component tray.
Note:
Do not remove outer heat shields.
3. Position the outer wrap on the wall and ensure it is
level. See Figure 6.9. A minimum of two screws must
be attached to the vertical wall studs. Secure with the
fasteners provided. See Figure 6.11(C) and Figure
6.12.
CAUTION!
Outer wrap and appliance MUST be in
-
stalled level for proper burner operation.
DO NOT REMOVE SCREW
(BOTH SIDES)
NOTE: The REVO-V12 has 4 screws
on each side of the firebox.
FIREBOX
COMPONENT TRAY
(DO NOT GRAB)
APPLIANCE TOP HEAT SHIELD
(DO NOT GRAB)
OUTER HEAT SHIELDS
DO NOT REMOVE
APPLIANCE
OUTER WRAP
Figure 6.8
Remove Firebox from Outer Wrap
4. Cut hole through wall as indicated in Figure 6.9. You
may use the appliance outer wrap as a guide.
WARNING! Risk of Fire!
Prevent contact with:
• Sagging or loose insulation
• Insulation backing or plastic
• Framing and other combustible materials
Block openings into the chase to prevent entry of blown-in
insulation. Make sure insulation and other materials are
secured.
Failure to maintain air space clearance may cause over-
heating and fire.
5. Frame around the edges of the firestop cut out to ensure
insulation does not come into contact with the vent pipe.
See Figure 6.10 and 6.12.
6. Install wall firestop with four screws. See Figure 6.10
and Figure 6.11(C).
7. Seal the wall firestop. See Section 6.A.