Release the
SETUP
button.
SETUP
LED1
will start blinking rapidly.
Within
5s
, start setting the time.
Press
SETUP
x
times. One press
corresponds to
1s
. Each pressing is signaled
by the lighting of the diode. If the button is
not pressed within these
5s
, the controller
will set the time to 0s.
SETUP
After
3s
from the last press, the
LED1
diode
will flash
3
times. The controller will
remember the settings and return to normal
operation.
OPEN ONLY FUNCTION
It facilitates entry-exit communication by ensuring that the gate does not close when
another person activates the gate using a manual control button or a remote control.
This
function only works with AUTO CLOSE enabled.
To
enable
the function, set the
AUTO CL
and
ONLY OP
switches to the
ON
position.
To
disable
the function, set the
ONLY OP
switch to the
OFF
position.
PHOTO CLOSE FUNCTION
Enables the gate to close faster and saves energy. During
opening
, after activation of the
photocells, the gate will stop and with
AUTO CLOSING
enabled, after detecting a passage,
the auto-closing time is shortened and the gate will close after
5 seconds.
When opening
the Wicket, when an obstacle appears in the light of the photocells, the gate will be
stopped.
To
turn on
the function, set the
PHOTO CL
switch to
ON
.
To
disable
the function, set the
PHOTO CL
switch to
OFF
.
CH2 / EZ OUTPUT FUNCTION
The controller is equipped with an additional potential-free NO type output. Depending on
the settings, it can perform two functions. In the first one (
CH2 / EZ
in the ON position), as
a switch for the electric door lock - to unlock the latch, the relay is turned on 0.5s before
starting the movement towards opening - switching time 3s. In this mode, the transmitters
assigned to the WICKET / CH2 function control the M1 leaf. In the second one (
CH2 / EZ
in OFF position), as a universal CH2 output channel, monostable working - it is controlled
by transmitters assigned to the WICKET / CH2 function.
ATTENTION!
In versions B9: 1.x.x / 1.0.x / x.x.x for CH2 / EZ setting in the OFF position, after pressing
the transmitter button assigned to the WICKET / CH2 function, the relay is turned on for
0.5s (door electric strike) and the M1 leaf (wicket) is activated
From version B9: 1.x.x / 1.1.x / x.x.x for CH2 / EZ setting in OFF position, after pressing
the transmitter button assigned to the WICKET / CH2 function, the relay is turned on for 3