Release the
SETUP
button.
SETUP
The
LED1
will flash rapidly.
Within
5s
, start setting the time.
Press
SETUP x
times. One press
corresponds to
15s
. Each pressing is
signaled by the lighting of the diode. If the
button is not pressed within these
5s
, the
controller will set the time to
0s.
SETUP
After
3s
from the last press, the
LED
will
flash 3 times. The controller will remember
the settings and return to normal operation.
If the AUTO CLOSE function was enabled
before programming, set the
AUTO CL
switch to the ON position.
AUTOCLOSE FUNCTION
When the gate stops, after the OPEN signal, the time set by the user is counted down,
after which the CLOSING will take place. The light shines during the countdown. For the
user's safety, photocells are required (so that the gate does not close when there is an
obstacle in its light!). Additionally, when the
PHOTO CLOSE
function is on, the photocells
will shorten the auto-closing time and after detecting the passage, the gate will close after
5 seconds. If less than 5s are left until automatic closing, each detected passage will cause
the countdown of an additional 5s. If the gate is in the fully open position, each signal
trying to activate it in the opening direction will start the countdown of the auto-closing
time.
To
turn on
the function, set the
AUTO CL
switch to the
ON
position.
Set the desired auto-closing time according
to the procedure.
SETTING THE AUTO-CLOSING TIME
To
disable
the function, set the
AUTO CL
switch to the
OFF
position.
SETTING THE AUTO-CLOSING TIME
We set it in the range from
15s
to
25min
with a step of 15s. By default:
6min
The
AUTO CL
switch must be in the
ON
position.
Hold down the
SETUP
button for less than
3s
. When the button is pressed, the
LED1
lights up.
SETUP
Release the
SETUP
button.
SETUP
The
LED1
will flash rapidly.
23