COOLING MODE
REGULATED
FANS
Fans normal temp.-regulated
THEATER
MODE
Fans low-noise temp. regulated
(reduced max. output)
FULL
Fans constant full speed
DISPLAY
DISPLAY
ROTATION
NORMAL
Normal orientation
ROTATE
180°
Inverted orientation
DISPLAY
INTENSITY
10 -
100
Control panel
display intensity in
%
TEMPERATURE
UNIT
°C
All temperature
readouts in Celsius
°F
All temperature
readouts in
Fahrenheit
DEFAULT SETTI NGS
FACTORY
DEFAULT
NO
Return all fixture settings except
calibration to factory defaults
YES
FIXTURE TEST
TEST ALL
Automatic test of all effects
including dimming
TEST DIMMER
Manually test LED groups only*
TEST EFFECTS
RED
Manually test individual effects*
COLOR = Virtual color wheel
GREEN
BLUE
CTC
COLOR
ZOOM
TEST PAN / TILT
PAN
Run automatic test of pan or tilt
functions. Press MENU button to
stop the test
TILT
INFORMATION
POWER ON TIME xxxxH
Display hours fixture powered on
since manufacture
LED HOURS
xxxxH
Display hours LEDs powered on
since manufacture
SW VERSION
Vx.x.x
Display currently installed
firmware version