48
Martin
®
ERA 150 Wash User Guide
Minimum distance to combustible material* ................................ 0.5 m (1.7 ft.)
Minimum clearance around fans and vents ................................ 0.5 m (1.7 ft.)
*Distance from fixture, not mounting bracket
Connections
AC power in/thru ............................................ Neutrik PowerCON TRUE1 TOP
DMX data in/thru ...................................................... Neutrik 5-pin locking XLR
Electrical
AC power ............................................................ 100-240 V nominal, 50/60 Hz
Typical power consumption .................................................................... 315 W
Typical half-cycle RMS inrush current at 240 VAC .................................. 8.7 A
Power supply unit ................................... Auto-ranging electronic switch mode
Recommended Miniature Circuit Breaker* ............................................ Type D
*Per IEC 60898/UL489/CSA C22.2 No. 5
Maximum power and current
100-120 V, 60 Hz .......................................... 3.8 A, 340 W, Power factor 0.99
200-240 V, 50 Hz .......................................... 1.5 A, 340 W, Power factor 0.97
*Measurements made at nominal voltage with all LEDs at full intensity.
Allow for a deviation of +/- 10%.
Thermal
Cooling ..................................... Forced air (temperature regulated, low noise)
Maximum ambient temperature (T
a
max.) ................................ 40° C (104° F)
Minimum ambient temperature (T
a
min) ........................................ 0° C (32° F)
Total heat dissipation* ................................................................. 1195 BTU/hr.
*Calculated, +/- 10%, at full intensity, full white
Approvals
Global CB Certification/IECEE ................... IEC 60598-2-17 (IEC 60598-1)
EU safety .................. EN 60598-2-17 (EN 60598-1), EN 62471, EN 62493
EU EMC.......................... EN 55015, EN 55032, EN 55035, EN 61000-3-2,
EN 61000-3-3, EN 61547
US safety ........................................................................................ UL 1573
US EMC...................................................................... FCC Part 15 Class B
Canadian safety ........................................................... CSA C22.2 No. 166
Canadian EMC ................................ ICES-003 Class B, ICES-005 Class B
Australia/NZ ......................................................................................... RCM
United Kingdom ................................................................................. UKCA
Summary of Contents for Martin ERA 150 Wash
Page 1: ...ERA 150 Wash User Guide ...
Page 46: ...46 Martin ERA 150 Wash User Guide Dimensions All dimensions are in millimeters ...
Page 51: ......