Electrical installation of the charging pole
DANGER!
Danger to life due to electric shock!
Before working on the cPP2 charging pole: Disconnect the power supply
and ensure that it remains permanently disconnected during work.
After completion of the mechanical installation, the charging pole is connected to the
power supply. Only the standard connection of the power supply line is described below:
The installation and connection of optional accessory components is not the subject of
these instructions, but is described in the instructions for the respective component.
NOTE!
The internal circuits are protected as standard by RCBO type A C32 10.03
(Residual current operated Circuit-Breaker with Overcurrent protection)
already installed per charging point.
In addition, the
supply line
must be limited to a
maximum current of 63 A
by an on-site
back-up fuse
.
Deviating country-specific standards (connection conditions) must be observed!
NOTE!
Please note that the charging pole may only be connected with
ONE
supply
cable with a maximum conductor cross-section of 50 mm² (max. 35 mm² with
wire end sleeve).
For the electrical assembly you need the following components:
•
Slotted screwdriver, min. blade width 6 mm (not included)
•
Stripping pliers for supply cable (not included)
NOTE!
The initial start-up of the charging station
MUST ALWAYS
be performed
by a qualified installer: The installer will be able to verify the correct
operation of the charging station or correct any malfunctions or
installation errors.
Installation and operating manual
cPP2
charging pole
Version: 1.0.2
21