7 - Fault finding
84
Position Lights Fuse
Two fuses are placed at the rear of the main printed circuit to protect the lighting circuit (position lights).
•
Remove screw (1) and rock the main printed circuit to access the
fuses.
•
Check and replace the defective fuse (7.5 A).
÷
Note: Spare fuses are available on the main printed circuit board.
÷
Note: Ensure that the replacement fuse has the same capacity as the original fuse.
Fuse test
The main circuit has “Autofuse” type spare fuses (1) and a “Maxifuse” (2).
To test a fuse.
•
Remove the fuse to be checked and place it in the fuse holder (3)
according to the model.
If the indicator (4) lights up, this means that the fuse is in good
working order. If not, use an “Autofuse” (1) or “Maxifuse” f(2)
replacement fuse.
÷
Note: Ensure that the replacement fuse has the same capacity as
the original fuse.