![Hardi SARITOR 4000 Operator'S Manual Download Page 79](http://html.mh-extra.com/html/hardi/saritor-4000/saritor-4000_operators-manual_597264079.webp)
77
Error messages
Cabin error codes
The messages below will be displayed when a fault appears on the system of the cab's air conditioning.
List of error codes
Transmission error codes
ERROR #
Description
Fault operation
01
High pressure switch - Wiring or cycling 2 in 1 minute
Heat mode - compressor clutch disabled
02
Low pressure switch - Wiring or open for 1 minute
Heat mode - compressor clutch disabled only while low pressure switch is open
03
Blower speed select pot open/shorted to power
Auto blower speed
04
Temperature select pot open/shorted to power
72°F Set point
05
Recirc. pot open/shorted to power
Not used on combine
06
Mode select pot open/shorted to power
Not used on combine
07
Cab temp sensor wiring - open, short, ground, power
Manual mode - compressor clutch disabled
08
Evap. temp sensor wiring - open, short, ground, power
Heat mode - compressor clutch disabled
09
Outlet temp sensor wiring - open, short, ground, power
Doesn’t limit blower speed on startup
10
Outside temp sensor wiring - open, short, ground, power
Not used on combine
12
Cab pressure sensor wiring
Not currently implemented
14
Clutch output fault (overcurrent, short to ground)
Not currently implemented
15
Defog light output fault (overcurrent, short to ground)
Not currently implemented
15
Defog light output fault (overcurrent, short to ground)
Not currently implemented
Error
codes
Description
Error
codes
Description
001
Low battery voltage
070
Loop error
002
Low battery voltage
071
PWM2 current loop error
003
12V sensor low supply voltage
074
Loop error pump 1
004
12V sensor high supply voltage
080
Brake pressure sensor signal out of range
005
5V sensor low supply voltage
083
CAN bus communication error: signal not received
006
5V sensor high supply voltage
084
High pressure sensor signal out of range
007
Stack overflow
092
Joystick sensor error
008
E2prom memory error
097
Analog mode selector sensor error
009
FLASH memory error
100
Joystick limitation control error
010
RS232 memory error
200
Offroad SD: high battery voltage
011
CAN bus connection error
201
Offroad SD: low battery voltage
012
Current return protection
202
Offroad SD: 12V supply voltage sensor out of range
020 to 045
Internal system error
051
MAF loading error
052
Inconsistent key
053
Inconsistent MAF
054
Inconsistent input/output
055
Error in sensitive parameter
056
SDPHASE code error
057
Checksum error
058
Min/Max error in parameter
rpm x100
SD
00
SD
00
54.5
P
OFF
7 - Fault finding
Summary of Contents for SARITOR 4000
Page 2: ......
Page 4: ......
Page 10: ...1 Welcome 8 ...
Page 64: ...5 Operation 62 ...
Page 84: ...7 Fault finding 82 Electrical incidents Main circuit fuses and relays U100163B ...
Page 92: ...Index 90 ...
Page 93: ......