7 - Fault finding
80
SPN
Component / Location
Description (Error location)
FMI
1322
Multiple cylinders
Misfire detected
11.12
1323
Single cylinder
Misfire detected (cylinder 1)
11, 12
1324
Single cylinder
Misfire detected (cylinder 2)
11, 12
1325
Single cylinder
Misfire detected (cylinder 3)
11, 12
1326
Single cylinder
Misfire detected (cylinder 4)
11, 12
1327
Single cylinder
Misfire detected (cylinder 5)
11, 12
1328
Single cylinder
Misfire detected (cylinder 6)
11, 12
1346
Misfire
Misfire detected with system reaction
0, 11
1450
Single cylinder
Misfire detected (cylinder 7)
11, 12
1451
Single cylinder
Misfire detected (cylinder 8)
11, 12
1638
Customer-specific sensor
Cable break or short circuit (sensor 2)
3, 4, 11, 12
1638
Customer-specific temperature
Outside target range with system reaction (temperature 2)
2, 11
2634
Main relay
Short circuit to Ubatt (relay 1)
3, 11
2634
Main relay
Short circuit to ground (relay 1)
4, 11
2634
Main relay
Short circuit to ground or emergency shut-off (relay 2)
7, 11, 12
2634
Main relay
Short circuit to ground or emergency shut-off (relay 3)
7, 11, 12
2791
EGR actuator (external)
Short circuit to Ubatt
3, 11
2791
EGR actuator (external)
Short circuit to ground
4, 11
2791
EGR actuator (external)
Cable break or ECU internal error
2, 5, 11
2791
EGR actuator (external)
Cable break or short circuit
2, 3, 4, 5
523212
CAN message
Missing (message “EngPrt” = engine protection)
11, 12
523216
CAN message
Missing (message “PrHtEnCmd” = Preheat and engine command
11, 12
523218
CAN message
Missing (message “RxCCVS” = cruise control)
11, 12
523222
CAN message
Missing (message “TCO1” = speedo signal)
11, 12
523238
CAN message
Missing (message “SwtOut” = switch outputs)
11, 12
523239
CAN message
Missing or value above target range (message “DecV1” = pseudo pedal)
2, 12
523240
CAN message
Missing (message “FunModCtl” = function mode control)
11, 12
523350
Multiple injectors
Short circuit (cylinder bank 1)
3, 4, 11, 13
523351
Multiple injectors
Cable break (cylinder bank 1)
5, 13
523352
Multiple injectors
Short circuit (cylinder bank 2)
3, 4, 11, 13
523353
Multiple injectors
Cable break (cylinder bank 2)
5, 13
523354
ECU internal error
Injector power stage A
2, 3, 12, 14
523355
ECU internal error
Injector power stage B
12
523370
Rail pressure
Compression test active: Rail-pressure monitoring is going to be disabled
11, 14
523420
ECU internal error
Watchdog counter exceeds maximum
11, 14
523450
Multi state switch
Cable break or short circuit, input voltage outside target range (switch 1)
2, 3, 4, 11
523451
Multi state switch
Cable break or short circuit, input voltage outside target range (switch 2)
2, 3, 4, 11
523452
Multi state switch
Cable break or short circuit, input voltage outside target range (switch 3)
2, 3, 4, 11
523470
Rail pressure limiting valve
Opening failure
2, 11, 12, 14
523470
Rail pressure limiting valve
Opening failure with system reaction
11, 12
523490
ECU internal error
Redundant shut-off conditions detected
3, 4, 11, 12
523500
CAN message
Time-out of at least one sent message
11, 12
Summary of Contents for SARITOR 4000