![Hardi SARITOR 4000 Operator'S Manual Download Page 83](http://html.mh-extra.com/html/hardi/saritor-4000/saritor-4000_operators-manual_597264083.webp)
7 - Fault finding
81
SPN
Component / Location
Description (Error location)
FMI
523550
Terminal 50
Engine start switch hangs
11, 12
523550
ECU internal error
Time processing unit (TPU) defective
2, 11
523561
Begin of injection period
Outside target range or missing (cylinder 1)
2
523562
Begin of injection period
Outside target range or missing (cylinder 2)
2
523563
Begin of injection period
Outside target range or missing (cylinder 3)
2
523564
Begin of injection period
Outside target range or missing (cylinder 4)
2
523565
Begin of injection period
Outside target range or missing (cylinder 5)
2
523566
Begin of injection period
Outside target range or missing (cylinder 6)
2
523567
Begin of injection period
Outside target range or missing (cylinder 7)
2
523568
Begin of injection period
Outside target range or missing (cylinder 8)
2
523600
ECU internal error
Serial communication interface defective
11, 12
523601
ECU internal error
Wrong voltage of internal 5V reference source 3
3, 4, 11
523602
Fan speed
Above target range with system reaction
2, 11
523604
CAN message
Missing (message “RxEngTemp” = engine temperature)
11, 12
523605
CAN message
Missing (message “TSC1-AE”)
11, 12
523606
CAN message
Missing (message “TSC1-AR”)
11, 12
523607
CAN message
Missing (message “TSC1-DE”)
11, 12
523608
CAN message
Missing (message “TSC1-DR”)
11, 12
523609
CAN message
Missing (message “TSC1-PE”)
11, 12
523610
CAN message
Missing (message “TSC1-VE”)
11, 12
523611
CAN message
Missing (message “TSC1-VR”)
11, 12
523612
ECU internal hardware monitoring
A recovery occurred which is stored as protected
11, 14
523612
ECU internal hardware monitoring
A recovery occurred which is not stored
11, 14
523612
ECU internal hardware monitoring
A recovery occurred which is visible in the error memory
11, 14
523612
ECU internal hardware monitoring
Overvoltage
3, 11
523612
ECU internal hardware monitoring
Undervoltage
4, 11
523613
Rail pressure
Positive deviation (speed dependent) outside target range
0, 11
523613
Rail pressure
Positive deviation (flow dependent) outside target range (=> Leakage!)
0, 11
523613
Rail pressure
Negative deviation (flow dependent) outside target range
0, 11
523613
Rail pressure
Negative deviation (speed dependent) outside target range
1, 11
523613
Rail pressure
Pressure above target range
0, 11
523613
Rail pressure
Implausible (leakage, injector needle blocked in open position)
2, 11
523615
Metering unit valve
Flow rate outside target range
3, 4, 11
523615
Metering unit valve
Not connected or output disabled
5, 11, 12
523615
Metering unit valve
Short circuit to Ubatt
11, 12
523615
Metering unit valve
Short circuit to ground
11, 12
523617
ECU internal error
Communication with chip CJ940 disturbed
11, 12
-
Customer-specific sensor
Cable break or short circuit (sensor 1)
2, 3, 4, 11
-
Customer-specific temperature
Outside target range with system reaction (temperature 1)
2, 11
Summary of Contents for SARITOR 4000
Page 2: ......
Page 4: ......
Page 10: ...1 Welcome 8 ...
Page 64: ...5 Operation 62 ...
Page 84: ...7 Fault finding 82 Electrical incidents Main circuit fuses and relays U100163B ...
Page 92: ...Index 90 ...
Page 93: ......