![Hardi SARITOR 4000 Operator'S Manual Download Page 65](http://html.mh-extra.com/html/hardi/saritor-4000/saritor-4000_operators-manual_597264065.webp)
63
Lubrication
General information
Always store lubricants in a clean, dry and cool place - preferably at a constant temperature to avoid contamination from
dirt and condensation. Keep oil filling jugs, hoppers and grease guns clean, and clean the lubricating points thoroughly
before lubricating. Avoid prolonged skin contact with oil products. Always follow the recommendations concerning
quantity. If no quantity is indicated, lubricate until new grease becomes visible.
To open the engine hood, see “Access to the engine” on page 31.
Table of recommended lubricants
÷
Note: The values in the table above are general capacities. Always use the level indicated by the gauge when filling.
Display of the frequency of maintenance
The following alert symbols appear in the display after 150 hours and 500 hours to indicate that maintenance work needs
to be performed on the sprayer:
1.
Maintenance after 150 hours of use.
2.
Servicing every 500 hours.
Message (1) appears only once after 150 hours to indicate that maintenance work is to be performed on the machine.
Message (2) appears periodically after 500 hours to indicate that maintenance work is to be performed on the machine.
Reset the time meter
•
Simultaneously press buttons (4) and (5) for 5 seconds to reset the maintenance hour meter.
÷
Note: Cancelling the message is to be performed only after the
maintenance work has been carried out.
Components
Capacity
Capacity (with filter)
Recommended lubricants
Engine Cummins QSB 6.7
19 quarts (18 liters)
19.5 quarts (18.5 liters)
Chevron Delo® 400 LE SAE 15W-40
Hydraulic Transmission and
Hydraulic system
26 gallons (100 liters)
Chevron Rando® HDZ ISO 046
Wheel gear boxes
3.2 quarts (3 liters)
Chevron Delo® Syn-Gear HD SAE 75W-90
Coolant
26.4 quarts (25 liters)
Chevron Delo® Extended Life (227811)
Prediluted 50/50 Coolant/Antifreeze - B
General lubrication
--
Universal Lithium grease, NLGI No. 2
SHELL RETINAX EP2, CASTROL LMX GREASE
1
2
rpm x100
54.5
P
OFF
5
4
6 - Maintenance
Summary of Contents for SARITOR 4000
Page 2: ......
Page 4: ......
Page 10: ...1 Welcome 8 ...
Page 64: ...5 Operation 62 ...
Page 84: ...7 Fault finding 82 Electrical incidents Main circuit fuses and relays U100163B ...
Page 92: ...Index 90 ...
Page 93: ......