3 - Description
60
BoomPrime (optional)
BoomPrime is a low pressure circulation system, which primes the spray boom tubes prior to spraying, ensuring a
homogeneous fluid in the boom tubes and in the MainTank. Below the illustration shows the BoomPrime system for the
boom. Components are explained in the diagrams for the liquid systems.
•
The BoomPrime system is attached to each end of a boom section (A).
•
The boom spray sections are fed into the middle of each section (B).
Liquid for BoomPrime is led through a valve (D) just before the flowmeter (F). This valve operates in opposite phase:
When priming, the direction of the liquid flow will be reversed. The liquid will be fed into the nozzle pipes from each end,
and they will then return any water back to the MainTank through the return hose for the distribution valves (C).
The BoomPrime pressure is adjusted by the handle on the control valve (E), which includes a pressure gauge.
For adjustment, see the section “BoomPrime Adjustment (Manual Version)” on page 86.
Operating State
Section Valves
BoomPrime Valve
Spraying
Open
Closed
Not spraying
Closed
Open
B
C
D
A A
A A
A A
A A
B
B
B
F
E
Summary of Contents for NAVIGATOR VPZ
Page 4: ...1 EU Declaration 4...
Page 72: ...3 Description 72...
Page 135: ...6 Maintenance 135 Lubrication Plan Boom Wings 10...
Page 174: ...6 Maintenance 174...
Page 182: ...7 Fault Finding 182...
Page 195: ...8 Technical Specifications 195 Hydraulic Diagrams Hydraulics for Boom of 21 24 Meters...
Page 196: ...8 Technical Specifications 196 Hydraulics for Boom of 27 28 Meters...
Page 198: ...8 Technical Specifications 198...
Page 204: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 N rre Alslev DENMARK...