3.2
Lift parameter chart
4
Installation of the equipment
Pre Installation
SELECTING SITE
:
Before installing your new lift, check the following points
.
OVERHEAD OBSTRUCTIONS
:
The area where the lift will be located should be free of
overhead obstructions such as heaters, building supports, electrical wires etc.
FLOOR REQUIREMENTS
:
Visually inspect the site where the lift is to be installed and
check if there is cracked or defective concrete. This lift must be installed on a solid level
concrete floor with no more than 2 degrees of slope. A level floor is suggested for proper
installation and level lifting. If a floor is of questionable slope, consider a survey of the site
and the possibility of pouring a new level concrete slab. This lift is designed to be installed
on a minimum of 180mm thick, 3500psi, steel reinforced concrete. Do not install this lift on
asphalt, wood, or any other surface other than described.
DO NOT
install this lift outdoors unless special consideration has been made to protect
the power unit from weather conditions.
The Power unit is not water proof!!!
DO NOT
begin installation with lift close to wall. It is necessary to leave adequate
clearance for installing safety linkage rods. Allow 1524mm for clearance.
(See pic)
NOTE
The power unit can be placed in two locations, front left or rear right
(See pic)
Total Height
2845mm
Lifting/Dropping Time
≈50s
The Maximum Lifting Height
2000mm
Overall length:
4826mm
Rated Load
4000kg
Motor Power
2.2kw
Working Voltage
230-415V 15A
Noise Level
≤70dB(A)
Oil Pressure
20MPa