C6: Heating rod start temperature (1
℃
-20
℃
): C6 is 2 degrees lower than C4,
otherwise it cannot be adjusted.
C7: Maximum room temperature alarm function (42
℃
-50
℃
): When the room
temperature exceeds this C7, the alarm signal is output and the Cold water
machine compressor stops working.
C8: Start mode, ON-machine starts when the machine is powered on,
OFF-powers on and presses the power button to start.
General parameter description:
※
All temperature measurement display range: -20
℃
~ 99.9
℃
.
※
When the following conditions occur during the adjustment, the conflict will be
caused, the adjustment will stop, and the buzzer will sound 3 alarms to indicate
that the adjustment is invalid:
.The set temperature of the constant temperature mode exceeds the value of
the upper limit temperature
C5;
.The set temperature of the constant temperature mode is lower than the value
of the lower limit
temperature C4;
.The heating rod start temperature is higher than (lower limit temperature
C4-2
℃
);
When the above error conflict occurs and cannot be adjusted, you can return
the conflicting items to modify them to resolve the conflict.
5.
Fault protection function:
Summary of Contents for HT3200-UV K Series
Page 1: ...3200 Hybrid UV printer installation instruction HT3200 UV_K...
Page 16: ...15...
Page 39: ...38 Select the communication port Select the printer model...
Page 40: ...39 Select lamp type Browse a path for TopJet...
Page 42: ...41 Install Click finish to continue...
Page 43: ...42 Install the driver for PCIE card...
Page 44: ...43 Accept and click next Continue...
Page 50: ...49...
Page 59: ...58 5 2 6 Heads parameter Setting...
Page 64: ...63 Clean all tubes with flush Connect the tubes with the heads As shown in pictures below...
Page 66: ...65 Put the head to the right position Discharge the protective fluid of the head...
Page 75: ...74 Modify the page header base point based on the margin...
Page 110: ...109 Cable diagram of HT3200D head configuration 2X5 Mode DA_YMCKKCMYWW Mode DA_YMCKKCMY_...
Page 111: ...110 Mode DA_CMYKW Mode DA_ _CMYKW...
Page 112: ...111 Mode DA_YMCKKCMYWW Mode DS_CMYK...
Page 113: ...112...