31
2.
Button function introduction:
AUTO: (Smart mode)
Entry method: Press once to enter the mode, press
AUTO k
ey
(
D1
)
again to display the room temperature, and automatically return to the
display water temperature after 3 seconds.
CONSTANT (constant temperature mode)
Entry method: same as smart mode
entry method and function
SET (Settings):
Entry method: Press
SET key
to enter the setting state, can adjust all
the default parameters from C0 to C8, no operation button for more than 10
seconds or press SET button to exit the setting and save the parameters.
- + (minus and plus key):
All parameters are modified by the plus or minus key.
(Up and down keys):
Press the up and down keys to switch from C0 to C8
when entering the SET state; press the up and down keys to adjust the UV lamp
power without entering the SET state (whether it is adjustable according to the
actual situation of the UV manufacturer)
QA
: phase A loss
QB
: phase B loss
QC
: phase C loss
QF
: phase sequence error
OK
:
three phase normal
Press and hold the SET button for 4 seconds to reset all set values to the initial
state.
3.Control mode selection and working mode details
CONSTANT (Constant temperature mode):
(factory default: 26
℃
)
D2 displays the current set temperature value, directly press the plus or minus
button to change the set value, real-time water temperature (D1) = set temperature
(D2)
±
return difference
value(C1). The setting range is 5
℃
- 40
℃
, the default
is 30
℃
. In addition, the set temperature value cannot exceed the
upper limit (C5), Lower limit (C4) temperature range.
Summary of Contents for HT3200-UV K Series
Page 1: ...3200 Hybrid UV printer installation instruction HT3200 UV_K...
Page 16: ...15...
Page 39: ...38 Select the communication port Select the printer model...
Page 40: ...39 Select lamp type Browse a path for TopJet...
Page 42: ...41 Install Click finish to continue...
Page 43: ...42 Install the driver for PCIE card...
Page 44: ...43 Accept and click next Continue...
Page 50: ...49...
Page 59: ...58 5 2 6 Heads parameter Setting...
Page 64: ...63 Clean all tubes with flush Connect the tubes with the heads As shown in pictures below...
Page 66: ...65 Put the head to the right position Discharge the protective fluid of the head...
Page 75: ...74 Modify the page header base point based on the margin...
Page 110: ...109 Cable diagram of HT3200D head configuration 2X5 Mode DA_YMCKKCMYWW Mode DA_YMCKKCMY_...
Page 111: ...110 Mode DA_CMYKW Mode DA_ _CMYKW...
Page 112: ...111 Mode DA_YMCKKCMYWW Mode DS_CMYK...
Page 113: ...112...