33
C3: Water shortage alarm delay time (1S
–
100S): Continue to work normally when
the water shortage time is detected is less than this value.
C4: Lower limit temperature setting (1
℃
-25
℃
). If it is lower than this value, it will
not be cooled; this value cannot be higher than the set temperature value of the
constant temperature mode.
C5: Upper limit temperature setting (25
℃
-50
℃
), the water temperature is kept
below the value of (C5+C1).
This value must be 2
℃
higher than the heating rod start temperature C6, and can
not be lower than the set temperature value of the constant temperature mode,
otherwise it cannot be adjusted.