HG2200/HG2200AT Operator’s
Manual
50 Hour
114 - Service
50 Hour
Change Engine Oil and Filter
(Initial Service)
Change engine oil after 50 hours of operation, and
every 100 hours thereafter.
To change:
1. While oil is warm, remove drain plug (3). Drain
oil and replace plug.
2. Remove filter (1) and replace with new filter
each time oil is changed.
3. Add DEO at fill until oil level is at highest
capacity on dipstick (2).
Clean Air Filter
Clean air filter after 50 hours.
To change:
1. Remove wing nut (1) to remove cover (2).
2. Remove and clean filter element (3). Replace if
needed. See “Change Air Filter” on page 126.
3. Wipe inside of housing (4) and wash cover.
4. Replace filter element and ensure it is seated
correctly.
5. Clean dust ejector valve (5).
6. Replace cover. If cover does not fit, filter
element is not properly locked into housing. Remove cover and element and repeat step 4.
Task
Notes
Change engine oil and filter
Initial service, DEO
Clean air filter
Check fuel lines
Grease bull wheel sprockets
MOB
Check hydraulic hoses
Grease mast pivots
EPG
Grease mast cable sheave
bearings
EPG
j64om037w.eps
2
3
1
j64om038w.eps
1
2
3
4
5
Summary of Contents for HG2200AT
Page 51: ...HG2200 HG2200AT Operator s Manual Battery Disconnect 50 Controls...
Page 75: ...HG2200 HG2200AT Operator s Manual Retrieve Tracked Unit 74 Transport...
Page 87: ...HG2200 HG2200AT Operator s Manual Finish Installation 86 Burst Pipe...
Page 129: ...HG2200 HG2200AT Operator s Manual As Needed 128 Service...
Page 133: ...HG2200 HG2200AT Operator s Manual Declaration of Conformity Information 132 Specifications...
Page 137: ...HG2200 HG2200AT Operator s Manual 136 Service Record Service Performed Date Hours...
Page 146: ......